Quality Service Since 2002

eRL-08 Electronic Resort Rental Lock - Latch

 

Retail Price: $US 499.99  $US 349.99
Save: 30% off

  • Model: eRL-08LATCH
  • In Stock

Please Choose:






Add to Cart:

Product Overview

eRL-08 Eleotronic Resort Rental Lock - Latch type

Product Overview:

The eRL-08 Rental Property Keyless Remote Access Control System is composed of two parts. One is the eRL-08 Remote Access Controller, a software program running on your own computer. The other is the eRL-08 Lock Device, the lock installed on the door of your rental property.

The eRL-08 Lock Device is a self contained, electronically controlled, battery powered, single door access control device.

The eRL-08 Remote Access Controller is used to remotely manage each eRL-08 Lock Device, generate Access Codes for the people whom you grant to access to your rental property at different restrained time, and also keeping each Access Code historical records.

There are no wire or wireless network connections between the eRL-08 Lock Devices and the eRL-08 Remote Access Controller. The remote access control function is realized by the 10-digit time sensitive Access Code using the latest encrypt/decrypt technologies. Therefore, you can grant access to your rental property, for different people, in whatever access time schedule you want, by issuing the Access Code generated by eRL-08 Remote Access Controller remotely, even when you are in a different country.

The eRL-08 Lock Device will control each code access time precisely according to each access time schedules encrypted in the Access Code.

Using eRL-08 Rental Property Keyless Remote Access Control System to manage your rental property, you can control your guests stay length from one hour to two years, and their check-in/check-out time at any hour of the day. You can control your employee's work term from one day to two years, and daily start/end work hour at any hour of the day. You can control your public facility (e.g. swimming pool) use term from one day to two years, and daily open/close time at any hour of the day. Also, for people who temporarily work on your property, (e.g. repair, painting, or maintenance), you can issue them a code which can be used on a predetermined date, for one entry time only. All such access control functions can be realized by clicking the start/end date on the calendar, start/end hour on the hour table, and the "Generate Code" soft button on your computer to generate an Access Code, then, you can email, phone, or fax the Access Codes to whomever you grant to access to your rental property, all within 30 seconds.

eRL-08 Rental Property Keyless Remote Access Control System is specially designed to meet your unique needs to manage your rental property. It uses revolutionary time sensitive Access Code, which is generated by your own computer, to allow you to instantly and remotely grant access to your rental properties for specific periods of time, without the need for a key or keycard.

Using eRL- 08 Rental Property Keyless Access Control System, you have a better way to control your property rental time.

Features

Features:
Material
Stainless steel cast alloy integrative structure.
Finishes
Silver or Gold
Keypad

12 alphanumeric stainless steel buttons.
Alps TACT Switch, 500,000 Cycle Operating Life.

Outside Handle
Rotate freely in locked mode to prevent malicious destroy of the lock.
Inside Handle
Never locked to meet fire exit requirements.
Handles
Right Hand or Left Hand
Unlock Way
Access Code:
1. Software-generated 10-digit Access Code.
2. User-created 3-6 digit easy to remember Personalized Code.
3. No time-related Key Code.

Physical Key:
Two Mechanical keys for emergency override, which cannot be duplicated.
Access Code Type

For Guest:
1. Short term stay - Control stay length from one hour to 32 days, check-in/check-out time at any hour of the day.
2. Long term stay - Control stay length from 32 days to 732 days (2 years).


For Personnel:
1. Short term staff - Control employment term from one day to 32 days, daily start/end work time at any hour of the day.
2. Long term staff - Control employment term from one month to 24 months (2 years), daily start/end work time at any hour of the day.
3. One time use code - Control the external service people to access the property only one time on appointed day.


For Facility
:
1. Short term use - Control use term from one day to 32 days, daily open/close time at any hour of the day.
2. Long term use - Control use term from one month to 24 months (2 years), daily open/close time at any hour of the day.
3. One time use code - Control the external service people to access the facility only one time on appointed day.

For Group:
One Group Access Code to access all eRL-08 Lock Devices which are set in the same Group.
1. Guest type Group Access Code - Control access to the same group eRL-08 Lock Devices from start date/time to end date/time per your preset.
2. Personnel type Group Access Code - Control access to the same group eRL-08 Lock Devices from start date to end date, daily access time from start hour to end hour per your preset.
3. Facility type Group Access Code - Control access to the same Facility group eRL-08 Lock Devices from start date to end date, daily access time from start hour to end hour per your preset.

User Code Capacity
1. Software-generated 10-digit Access Code - Unlimited
2. User-created 3-6 digit easy to remember Personalized Code - 200
Disabled Code Capacity
Up to 50 valid Access Codes can be disabled at the same time.
Power
4 Standard alkaline AA Batteries. Typically lasting 1-2 years under normal operating conditions.
Low Power Alert
1. When the battery voltage is below 4.4V, the visible and audible alarm will alert you each time after successfully unlocked.
2. The eRL-08 Remote Access Controller software will automatically remind you to replace the batteries.
Operation Indication
Green LED, red LED, and buzzer.
Internal Clock
1. < ±5 minutes average deviation per year.
2. Backup power can keep clock running for 24 hours if the lock batteries are failure.
3. Automatic Daylight Savings Time and Leap Year correction.
Programming Method
Three simple keypad commands:
1. Change the Key Code when first time to setup the lock.
2. Adjust the date/time in lock when needed.
3. Disable a valid Access Code when needed.

Operation Temperature

Outdoor Part: -40ºF to 140ºF (-40ºC to 60ºC).
Indoor Part: 23ºF to 140ºF (-5ºC to 60ºC).

Keypad ESD Susceptibility

Air > 15KV
Contact > 8KV

Weather
Weather Resistant.
Lock Dimensions
3" X 5" X 7" (76mm X 127mm X 178mm)
Weight
4 lbs. (1.8Kg)
Latch
Adjustable backset from 2 3/8" to 2 3/4" (60mm to 70mm) with1/2" (13mm) throw.
Door Thickness
Fits doors 1 3/8" to 1 3/4" (34mm to 45mm) thick.
What Included


1. 2-3/8" and 2-3/4" latches
2. Latch strike plate
3. Latch strike lining box
4. Inside and outside rubber gaskets
4. Spanner
5. Wood screws
6. Two emergency override keys
7. One CD (software and manuals)
Installation
Non-professional, DIY.
Installation
1 Year Manufacturers Warranty
    Specifications
  • Power supply: 6V, 4 standard AA alkaline batteries (included)
  • Battery Life: Open more than 15000 times under normal circumstance.
  • Battery life-- lasts for more then 15,000 openings under normal conditions (Max. 2yrs).
  • Adjustable latch will accomidate 2-3/8" and 2-3/4" backset
  • Includes two mechanical keys for emergency override use
  • Personalized Pin Digits: 3-6 for easy remembering
  • User Capacity: 199

Installation

    Installation:
  • Door material: Metal Or Wooden Door
  • Fit door thickness from 1 3/8" to 1 3/4" (34mm to 45mm) thick.
  • Adjustable latch: 2 3/8 or 2 3/4 inch backset (60mm to 70mm) with 1/2" (13mm) throw.
  • Fit a standard 2-1/8" diameter hole.

Software

eRL-08 Remote Access Controller features
The eRL-08 Remote Access Controller is software in the CD which comes with your order. The software should be installed on your own computer. The major function of the eRL-08 Remote Access Controller is to provide an easy to use, secure, and manageable solution for your daily property rental management.
Operation System
Windows 2000, Windows XP, or Windows Vista.
Security
1. Login password protection.
2. Automatically logout.
Lock Device Capacity
Manage up to one million eRL-08 Lock Devices.
Access Code Trace Capacity
Trace up to one million Access Codes.
Access Code Type

For Guest:
1. Short term stay - Control stay length from one hour to 32 days, check-in/check-out time at any hour of the day.
2. Long term stay - Control stay length from 32 days to 732 days (2 years).


For Personnel:
1. Short term staff - Control employment term from one day to 32 days, daily start/end work time at any hour of the day.
2. Long term staff - Control employment term from one month to 24 months (2 years), daily start/end work time at any hour of the day.
3. One time use code - Control the external service people to access the property only one time on appointed day.


For Facility
:
1. Short term use - Control use term from one day to 32 days, daily open/close time at any hour of the day.
2. Long term use - Control use term from one month to 24 months (2 years), daily open/close time at any hour of the day.
3. One time use code - Control the external service people to access the facility only one time on appointed day.

For Group:
One Group Access Code to access all eRL-08 Lock Devices which are set in the same Group.
1. Guest type Group Access Code - Control access to the same group eRL-08 Lock Devices from start date/time to end date/time per your preset.
2. Personnel type Group Access Code - Control access to the same group eRL-08 Lock Devices from start date to end date, daily access time from start hour to end hour per your preset.
3. Facility type Group Access Code - Control access to the same Facility group eRL-08 Lock Devices from start date to end date, daily access time from start hour to end hour per your preset.

Reservation Check
One click on Check Reserved soft button to show all reservation list.
Expired Access Code
1. Automatically display expired Access Codes in real time.
2. One click to delete all expired Access Codes for a selected lock.
Lock Battery Replacement Reminder
Automatically remind eRL-08 Lock Device batteries replacement.
Daylight Saving Time
Automatically adjust Daylight Saving Time.
Database Backup/Restore
Backup/Recover tools to protect database if computer broke down.

eRL-08 Remote Access Controller screen shots:

Click on image to view full size images.


Login Management

Lock Management

Lock Management - Add New Lock

Code Generation - For Guest

Code Generation - For Personnel

Code Generation - For Facility

Code Generation - Code Detail

History Code - Invalid codes in pink color

Additional Images






Your IP Address is: 38.107.191.111
Copyright © 2003-2009 Kinglock.com A division of CA-Technology, Inc
Site Design by designerxp
RSS Product Feed :: eRL-08 Electronic Resort Rental Lock - Latch